한국필터시험원에서

맑은공기를 책임지겠습니다

Air & Gas Filter Test

Air Filter & Gas Filter Test

1. HEPA filter test For nuclear power

HEPA Filter, a core component of the air cleaning system, must confirm its performance through verification tests and ensure its quality through product testing.

HEPA Filter

As a High-Efficiency Particulate Air filter, it must exhibit an efficiency of at least 99.97% when tested with a consumable expanded filter media, dry filter, and monodisperse generation 0.3 μm test aerosol particles in a hard case that accommodates the entire filter media.

HEPA filter qualification test for nulcear grade by ASME AG-1

New or revised filter designs shall require qualification testing prior to acceptance and production. Filter designs shall be requalified at least 5 yr. Tests shall be performed and certified by an independent test facility

HEPA filter production test for nuclear grade by ASME AG-1

Each HEPA filters whose performance has been qualification tests shall be tested before being delivered to nuclear power facilities. Tests shall be performed and certified by an independent test facility

Applicable Standards

MIL-STD-282 Filter Units, Protective Clothing. Gas-Mask, Components and Related Products Performance Test Methods
⁠KEPIC MHB FC & FK HEPA Filter
⁠ASME AG-1 FC & FK HEPA Filter
⁠UL 586 8 Efficiency and Resistance Tests
⁠KS A 4812 l HEPA Filter for Radioactive Aerosols

2. Industrial HEPA filter

HEPA filter is a filter with an efficiency of at least 99.97% as tested with 0.3μm monodisperse test aerosol particles, and its performance must be proven as a core component of air purification technology.

Applicable Standards

⁠KS B 6141 | Air Filter Units for Ventilation

⁠KS B 6740 | Cleanroom-Air Filters-Test Methods

⁠UL 586 | High-Efficiency, Particulate, Air Filter Units
⁠UL 900 | Standard for Air Filter Units
IEST-RP-CC001.3 | HEPA and ULPA Filters
⁠JIS Z 4812 | HEPA Filters for radioactive aerosols
⁠JIS B 9908 | Test method of air filter units for ventilation and electric air cleaners for ventilation
⁠* 기타 고객 요구 사항

3. Charcoal Filter For nuclear power

The Charcoal Filter of the air purifier system shall verify its performance through a verification test and prove its performance through a product test.

The Charcoal Filter is an air and gas treatment system filter that adsorbs radiation materials in the air in nuclear facilities and removes harmful substances from the air and harmful gases generated in exhaust facilities.

Performance shall be verified by conducting a full product test before delivery

Charcoal Filter For nuclear power qualification test

The performance of the Carbon Filter for nuclear power shall be performed by R-11, and the removal efficiency shall be maintained at least 99.95%.

Applicable Standards

KEPIC MHB FD & FE & FH ASME AG-1 FD & FE & FH

1. Multiplex/Industrial Facilities

Leakage test after installing HEPA filter

When leakage tested with fine aerosol (DOP) particles, the removal efficiency shall be maintained at least 99.95%.

Leakage test after installing HEGA filter

As a granular activated carbon adsorption filter that adsorbs gaseous pollutants, it shall be tested with R-11 refrigerant gas and maintain a removal efficiency of at least 99.95%.

Applicable Standards

+ ASME N509
+ ASME N510
+ ASME N511
+ ASME AG-1
+ KEPIC MH

Test cycle

As a in-service leakage test of the air cleaning unit, a periodic test is performed according to the relevant law, code and standard after the filter is replaced.

Interval of leakage test

+Industrial Air Purification Facility (24 months)

+Cleanroom/Clean bench: ISO grades 1 to 5 (6 months), ISO grades 6 to 9 (12 months)

Test method

2. Performance Test of Mobile Air Cleaning Unit and HEPA Vacuum Cleaner

Performance Test of Mobile Air Purifier

Performance Criteria

When tested with fine aerosol particles, the mechanical removal efficiency at the rated flow rate shall be maintained at least 99.95%.

Applicable standards

+ ASME N510

+ KS I ISO 14644-3

Test cycle

As a on-site leakage test of the air cleaning unit, a periodic test is performed according to the relevant law after the filter is replaced.

+ Industrial Air Purification Facility (24 months)

Test method

HEPA  Vacuum Cleaner

Fine particles (PM2.5 or less) that may occur in the air, asbestos particles and dust generated during asbestos dismantling work should be collected in HEPA vacuum cleaner

Performance Criteria

The performance test of the HEPA vacuum cleaner shall be maintained at least 99.95% of the removal efficiency when tested with fine aerosol particles.

Test cycle

As a on-site leakage test of the air cleaning unit a periodic test is performed according to the relevant law after the filter is replaced.

+ Industrial Air Purification Facility (24 months)

Test method